* Initial implementation of multi-printer support. * Always show device dropdown and add bambu_diagnose for multi-printer troubleshooting. * Add multi-AMS support: per-unit snapshot/usage tracking, grouped dashboard panels with real type labels, and dual-nozzle card UX fixes. Fixes a real-world AMS info-code parsing bug found by inspecting live H2C data. * Add Vortek hotend rack tracking: per-SN registry with slot mapping confirmed against live MQTT capture, plus a fallback for non-inductive nozzles (e.g. H2C's fixed left nozzle) shown read-only without fabricated identity. New dashboard card hides entirely on printers with no Vortek/nozzle-info data at all.
69 lines
2.1 KiB
Python
69 lines
2.1 KiB
Python
import pytest
|
|
|
|
from bambu_run.diagnostics import redact_diagnostics, build_diagnostics_report
|
|
|
|
|
|
def test_redacts_password_and_token_like_keys():
|
|
data = {"BAMBU_PASSWORD": "hunter2", "access_token": "abc123", "ok": "fine"}
|
|
|
|
redacted = redact_diagnostics(data)
|
|
|
|
assert redacted["BAMBU_PASSWORD"] == "***REDACTED***"
|
|
assert redacted["access_token"] == "***REDACTED***"
|
|
assert redacted["ok"] == "fine"
|
|
|
|
|
|
def test_masks_known_identifier_keys_partially():
|
|
data = {"dev_id": "31B8BP592601478", "tray_uuid": "EE37828FA8844DE1AB12"}
|
|
|
|
redacted = redact_diagnostics(data)
|
|
|
|
assert redacted["dev_id"] == "31B8...1478"
|
|
assert redacted["tray_uuid"] == "EE37...AB12"
|
|
|
|
|
|
def test_short_identifier_values_fully_masked():
|
|
data = {"dev_id": "short"}
|
|
|
|
redacted = redact_diagnostics(data)
|
|
|
|
assert redacted["dev_id"] == "***"
|
|
|
|
|
|
def test_recurses_into_nested_structures():
|
|
data = {"devices": [{"dev_id": "31B8BP592601478", "name": "RNL-H2C"}]}
|
|
|
|
redacted = redact_diagnostics(data)
|
|
|
|
assert redacted["devices"][0]["dev_id"] == "31B8...1478"
|
|
assert redacted["devices"][0]["name"] == "RNL-H2C"
|
|
|
|
|
|
def test_no_redact_passthrough_keeps_original_values():
|
|
data = {"dev_id": "31B8BP592601478", "BAMBU_PASSWORD": "hunter2"}
|
|
|
|
result = redact_diagnostics(data, redact=False)
|
|
|
|
assert result == data
|
|
|
|
|
|
def test_build_diagnostics_report_structure():
|
|
devices = [{"dev_id": "SERIAL-A", "name": "Printer A", "dev_product_name": "H2C"}]
|
|
raw_payloads = {"SERIAL-A": {"device": {"extruder": {"info": []}}}}
|
|
|
|
report = build_diagnostics_report(devices, raw_payloads)
|
|
|
|
assert report["device_count"] == 1
|
|
assert "generated_at" in report
|
|
assert report["devices"][0]["device_info"]["dev_id"] == "SERIAL-A"
|
|
assert report["devices"][0]["raw_mqtt_payload"] == {"device": {"extruder": {"info": []}}}
|
|
|
|
|
|
def test_build_diagnostics_report_handles_missing_payload():
|
|
devices = [{"dev_id": "SERIAL-A", "name": "Printer A"}]
|
|
|
|
report = build_diagnostics_report(devices, raw_payloads={})
|
|
|
|
assert report["devices"][0]["raw_mqtt_payload"] is None
|
|
assert report["devices"][0]["note"] == "No MQTT data received within the listen window."
|