Compare commits
1 Commits
master
...
smets2_uni
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
e8a946a68b |
@@ -71,6 +71,9 @@ def store_series(connection, series, metrics, rate_data):
|
|||||||
|
|
||||||
def fields_for_measurement(measurement):
|
def fields_for_measurement(measurement):
|
||||||
consumption = measurement['consumption']
|
consumption = measurement['consumption']
|
||||||
|
conversion_factor = rate_data.get('conversion_factor', None)
|
||||||
|
if conversion_factor:
|
||||||
|
consumption *= conversion_factor
|
||||||
rate = active_rate_field(measurement)
|
rate = active_rate_field(measurement)
|
||||||
rate_cost = rate_data[rate]
|
rate_cost = rate_data[rate]
|
||||||
cost = consumption * rate_cost
|
cost = consumption * rate_cost
|
||||||
@@ -149,6 +152,9 @@ def cmd(config_file, from_date, to_date):
|
|||||||
|
|
||||||
g_mpan = config.get('gas', 'mpan', fallback=None)
|
g_mpan = config.get('gas', 'mpan', fallback=None)
|
||||||
g_serial = config.get('gas', 'serial_number', fallback=None)
|
g_serial = config.get('gas', 'serial_number', fallback=None)
|
||||||
|
g_meter_type = config.get('gas', 'meter_type', fallback=1)
|
||||||
|
g_vcf = config.get('gas', 'volume_correction_factor', fallback=1.02264)
|
||||||
|
g_cv = config.get('gas', 'calorific_value', fallback=40)
|
||||||
if not g_mpan or not g_serial:
|
if not g_mpan or not g_serial:
|
||||||
raise click.ClickException('No gas meter identifiers')
|
raise click.ClickException('No gas meter identifiers')
|
||||||
g_url = 'https://api.octopus.energy/v1/gas-meter-points/' \
|
g_url = 'https://api.octopus.energy/v1/gas-meter-points/' \
|
||||||
@@ -184,6 +190,8 @@ def cmd(config_file, from_date, to_date):
|
|||||||
'gas', 'standing_charge', fallback=0.0
|
'gas', 'standing_charge', fallback=0.0
|
||||||
),
|
),
|
||||||
'unit_rate': config.getfloat('gas', 'unit_rate', fallback=0.0),
|
'unit_rate': config.getfloat('gas', 'unit_rate', fallback=0.0),
|
||||||
|
# SMETS1 meters report kWh, SMET2 report m^3 and need converting to kWh first
|
||||||
|
'conversion_factor': (float(g_vcf) * float(g_cv)) / 3.6 if int(g_meter_type) > 1 else None,
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|||||||
@@ -25,3 +25,9 @@ mpan = 12345
|
|||||||
serial_number = 12A3456
|
serial_number = 12A3456
|
||||||
standing_charge = 16.80
|
standing_charge = 16.80
|
||||||
unit_rate = 3.03
|
unit_rate = 3.03
|
||||||
|
# 1 for SMETS1 meters, 2 for SMETS2 meters
|
||||||
|
meter_type = 1
|
||||||
|
# volume correction factor, and calorific values used to convert SMETS2 consumption from m^3 to kWh
|
||||||
|
# Defaults are typically used values. Your energy bill will show you the values used for your supply.
|
||||||
|
volume_correction_factor = 1.02264
|
||||||
|
calorific_value = 40
|
||||||
|
|||||||
Reference in New Issue